TECHNICAL DATA SHEET
*Low NOx wall-mounted boiler for heating and instant hot water production
*Installation type: B11BS
*NOx emission class 6
*Natural draft flue gas exhaust
*Microprocessor electronic board with automatic regulation of ignition power and maximum heating
*Automatic ignition with flame ionization control
*Degree of electrical protection against water IP X4D
*Low NOx atmospheric burner
*Stainless steel plate sanitary heat exchanger
*Heating system expansion vessel
*Motorized diverter valve
Sime Vera 25 OF 25kW Low Nox Open Chamber Methane Boiler
Product Code: 8110470
Seasonal heating energy efficiency class C
Seasonal heating energy efficiency % 78.4
Heating sound power dB (A) 59
Health energy efficiency class A
Health energy efficiency % 80.3
Declared health load profile XL
HEATING PERFORMANCE
Heating adjustment range °C 20/80
Water content in the boiler: 3.15 l
Maximum operating pressure bar 3
Maximum operating temperature °C 85
Expansion vessel capacity 8 l
HEALTHCARE SERVICES
Nominal heat output kW 23.0
Reduced thermal output kW 10.0
Sanitary regulation range °C 10/60
Specific sanitary flow rate (EN 13203) l/min 10.0
Continuous sanitary flow rate (∆t 25/35°C) l/min 12.3/8.8
Minimum sanitary flow rate l/min 2.2
Min/max sanitary pressure bar 0.4/7.0
Dimensions HxWxD mm 700x400x250
TRUE OF 
Low NOx wall-mounted boiler for heating and instant hot water production
Installation type: B11BS
NOx emission class 6
Natural draft flue gas exhaust
Microprocessor electronic board with automatic regulation of ignition power and maximum heating
Automatic ignition with flame ionization control
Degree of electrical protection against water IP X4D
Low NOx atmospheric burner
Stainless steel plate heat exchanger
Heating system expansion vessel
Motorized diverter valve
Electronic gas valve for combustion feedback
High-efficiency, low-energy system pump (ErP)
Double element heating probe with safety thermostat functions
Smoke safety device that interrupts the flow of gas to the burner in the event of a blocked chimney and/or lack of draught
3 bar system safety valve
Anti-blocking function of the pump and diverter valve that activates automatically every 24 hours if there have been no heat requests
Antifreeze function that activates automatically if the water temperature in the boiler falls below the value set in the “tS 1.0” parameter and, in the presence of an external probe, if the external temperature falls below the value set in the “tS 1.1” parameter
Chimney sweep function that lasts 15 minutes and facilitates the task of qualified personnel in measuring the parameters and combustion efficiency and in checking the gas pressures at the nozzles
Control panel equipped with display with self-diagnosis with numeric codes
Knobs for regulating heating and domestic hot water temperatures
Provision for connection of SIME HOME remote control (optional)
Hydraulic fitting protection to be positioned under the boiler code 8094531 (optional)
Integrated climate control Hydraulic pressure switch that blocks the boiler in case of lack of water
Manual system loading device Water pressure control hydrometer
Suitable for operation in a partially protected place according to EN 15502, with a maximum ambient temperature of 60°C and a minimum of - 5°C. Brass system connections (DIN)
CONTINUE SHOPPING
!