TECHNICAL DATA SHEET
Niagara Advance combines technology with the convenience of two 20-liter boilers. Even the most demanding domestic hot water needs are met in every situation.
Chaffoteaux Niagara Advance 25 kW Condensing Boiler Complete with Flue Gas Exhaust Kit
Product Code: 3310626
Methane, LPG, and propane gas operation without the need for a kit. Conversion is achieved through combustion control by selecting the gas type from the technical menu.
Nominal heat output in heating max/min (Hi) Qn kW 22/2,5
Nominal heat output in heating max/min (Hs) Qn kW 24.4/2.8
Nominal heat output in domestic hot water max/min (Hi) Qn kW 26.0/2.5
Nominal heat output in domestic hot water max/min (Hs) Qn kW 28.9/2.8
Max/min heating power (80°C-60°C) Pn kW 21.5/2.3
Max/min heating power (50°C-30°C) Pn kW 23.6/2.6
Max/min useful power for sanitary use Pn kW 24.9/2.4
Combustion efficiency (flue gas) % 97.4
Efficiency at nominal heat output (60/80°C) Hi/Hs % 97.7/87.9
Efficiency at nominal heat output (30/50°C) Hi/Hs % 106.7/96.1
Yield at 30% of Qn
with return to 30°C Hi/Hs % 109.7/98.8
Efficiency at minimum (60/80°C) Hi/Hs % 93.5/84.2
Performance stars (dir. 92/42/EEC) ****
NOx Class 6
Flue gas temperature (G20) (80°C-60°C) °C 64
CO2 content (G20) (80°C-60°C) % 8.8
CO content (0%O2) (80°C-60°C) ppm 81.0
O2 content (G20) (80°C-60°C) % 4.3
Maximum smoke flow rate (G20) (80°C-60°C) kg/h 2.4
Excess air (80°C-60°C) % 26
Condensed pH pH 3.2
Maximum quantity of condensate l/h 26
HEATING CIRCUIT
Expansion vessel pre-charge pressure bar 1
Maximum heating pressure bar 3
Expansion vessel capacity 8 l
Heating temperature min/max (high temperature range) °C 35 / 82
Heating temperature min/max (low temperature range) °C 20 / 45
HEALTHCARE CIRCUIT
Min/max sanitary temperature °C 40 / 65
Specific flow rate in sanitary water (10 min. with ∆T=30°C l/min 13.2
Instantaneous quantity of hot water ∆T=25°C l/min 15.4
Instantaneous quantity of hot water ∆T=35°C l/min 11.0
Health comfort stars (EN13203) ***
Minimum hot water withdrawal l/min 2
Max/min domestic water pressure bar 7.0 / 0.3
ACS storage capacity l 40
Power supply voltage/frequency V/Hz 230 / 50
Total absorbed electrical power W 84.7
Circulator energy efficiency index EEI ≤ 0.23
Minimum ambient temperature for use °C >0
Electrical system protection rating IP X5D
Dimensions (Height x Width x Depth) 900 x 600 x 460 mm
Weight 42.5 kg
NIAGARA ADVANCE 
MAXIMUM PERFORMANCE
New single-coil primary exchanger in stainless steel.
Passage sections increased by 142% compared to the previous version.
1 m more head.
Seasonal yield at 94%.
Class A+ achievable with thermoregulation.
Performance certified by the TÜV RHEINLAND Group.
MAXIMUM COMFORT
Modulation ratio 1:10.
Optimized internal silencer.
SRA function.
Gas conversion with kit included as standard.
Ready for Chaffolink connectivity.
HEALTH COMFORT
40-litre reserve thanks to two stratified stainless steel accumulators.
Permanent availability of domestic hot water even with empty accumulators.
Domestic hot water performance ***, maximum level foreseen by the EN 13203 standard.
Flow rate up to 19.8 l/min with ΔT = 25ºC.
Integrated 2-litre sanitary expansion vessel.
EASY INSTALLATION
Installation in partially protected places.
Flue pipes 80, 60, 50 mm.
Intuitive electrical connections.
CONTINUE SHOPPING
!