TECHNICAL DATA SHEET
Built-in WiFi digital chronothermostat with weekly programming. NEXU WiFi allows you to manage your home comfort at any time of day, both inside and outside the home, simply and intuitively via a dedicated app.
Orbis NEXU WiFi FSV OB326210 chronothermostat
Program 4 or 6 daily scenarios of your choice, which can be varied for the 7 days of the week
Set up to 6 daily temperature levels
Select the operating mode:
Automatic
Temporary manual
Permanent Manual (Thermostat)
Extend the current scenario time up to 3 hours
Turn the Chronothermostat off in OFF mode or Antifreeze temperature for a holiday period
Correct the measured temperature reading
Activate the Outgoing Geolocation service which measures the distance of the position from the installation site and if this goes beyond the set limit, the user receives a WARNING, which asks if he wants to lower the Temperature in advance from the Comfort level to the Saving level
Share the management of the Chronothermostat with other users
Manage multiple Chronothermostats installed in the same home or in different locations
Alternatively, you can intervene on the NEXU WiFi Chronothermostat to:
Adjust the temperature in permanent manual mode (Thermostat) or temporary
Adjust the Differential and Antifreeze Temperature
Turn off the thermostat and lock the keypad
Temperature and operating status are displayed on a large backlit display
Backlit touch-sensitive keys
App available for iOS and Android devices
Possibility of being managed also via voice commands with the use of
Voice assistants (Google Home and Alexa)
TECHNICAL CHARACTERISTICS 
Power supply: 230 V AC 50-60 Hz
Contact rating: 5 (1) A at 250 V AC
Contact type: Simple opening
Regulation type: ON-OFF
Differential: Adjustable from 0.2°C to 1°C (default 0.2°C)
Temperature accuracy: ± 1 °C
Resolution: 0.1°C
Temperature regulation: From +5 °C to +35 °C
Antifreeze temperature adjustment: From +1 °C to +9 °C (default +5 °C)
Temperature reading correction: From -3.5 °C to +3.5 °C
Measured temperature display: From 0 °C to +50 °C
Operating temperature: 0°C to +50°C
Display: Negative backlight LCD
Degree of protection: IP 20
Protection class: Class II in correct installation condition
Installation: Wall or on 503 box (3 modules)