TECHNICAL DATA SHEET
A heat pump with silent and eco-friendly efficiency
This series of air-to-water heat pumps with eco-friendly R32 gas and a low environmental impact meets the winter and summer air conditioning needs of small and medium-sized residential and commercial systems. All units are suitable for outdoor installation and, being able to produce water up to 65°C, can be used in radiant systems, fan coils, radiators, and for the indirect production of domestic hot water (DHW) via an external boiler.
Ferroli Reversible Monobloc Heat Pump Model OMNIA M 3.2 12 kW With Compressor Including Control and Integrated Wi-Fi Code 2CP000HF
Energy class in heating at 35°C: A+++
Energy class in heating at 55°C: A+++
SCOP heating with water set to 35°C: 4.81
SCOP heating with water set to 45°C: 3.45
SEER cooling with water set at 7°C: 4.89
SEER cooling with water set at 18°C: 7.10
Useful power in heating with water set at 35°C: 12.1 kW
Useful power in heating with water set at 45°C: 12.3 kW
Useful power in heating with water set at 55°C: 11.9 kW
Power consumption with water set at 35°C: 2.44 kW
Power consumption with water set at 45°C: 3.32 kW
Power consumption with water set at 55°C: 3.90 kW
Compressor type: Twin Rotary DC
Number of compressors: 1
Number of refrigeration circuits: 1
Fan Type: DC Axial
Number of fans: 1
Expansion vessel volume: 2 litres
Water safety valve calibration: 3 bar
Minimum system water content: 15 litres
Sound power level in heating mode: 53 ~ 60 dB(A)
Sound power level in cooling : 52 ~ 60 dB(A)
Dimensions (WxHxD): 1385x865x526 mm
Weight: 129 kg
OMNIA M 
The OMNIA M 3.2 monobloc range has energy class A++ for the production of water at 55ºC and A+++ for water produced at 35°C
Compact outdoor unit. More space available.
Thanks to the adoption of a compact and small-sized unit, especially for the more powerful models, OMNIA M 3.2 can be easily placed outside the house, ensuring more available space inside.
Quick and easy installation
Being a monoblock unit, installation costs and times are significantly reduced. Refrigerant interconnection between the units is not necessary, as the entire refrigerant circuit is contained within the device. It is not even necessary to make a fuel connection or create a flue gas exhaust duct. Furthermore, the device includes all the hydraulic components necessary for correct and quick connection to the hydraulic heating and DHW system.
Ideal combination with low temperature systems
The OMNIA M 3.2 range can be easily installed in combination with low temperature systems, connecting fan coils, radiators, underfloor heating, to obtain maximum energy efficiency and maximum home comfort.
Easy integration with an existing boiler
OMNIA M 3.2 can be combined and integrated with any boiler in the system. Controlling the device, based on the outside temperature and required operating conditions, optimizes heat production for heating and domestic hot water, using the most efficient device.
Production of hot water at 65°C with low external temperature
The OMNIA M 3.2 range is capable of providing hot water at 60°C with an external temperature of up to -15°C and at 40°C with an external temperature of up to -25°C, without any type of support/accessory. At cold but positive temperatures, OMNIA M 3.2 can produce hot water up to 65°C.
Protects hydraulic components from freezing without the need to add glycol
If low outside temperatures are detected, the circulation pump and the electric antifreeze heater of the plate heat exchanger are activated, thus preventing the hydraulic components from freezing. There is therefore no need to add glycol to the system. 
Control system Operating principle
The general control system allows monitoring of all inverter system functions and the correct operation of the compressor. It also incorporates regulation algorithms using predefined climate curves that can be selected by the customer, management of a domestic hot water circuit, setting of time slots to limit noise during the night, alarm reporting, prevention of pump blockages, and integration with external heat generators. The user interface consists of a wired remote controller that allows management of:
Management of 2 distinct zones, direct + mixed. The unit is able to manage the pumps of both zones and, for the mixed one, the mixing valve and water delivery temperature probe.
Photovoltaic and Smart Grid Management The management of a photovoltaic system and the “smart grid” function is guaranteed by 2 digital inputs on the PCB with specific operating logics
Heating and cooling system The unit activates in hot or cold mode, it works by modulating the frequency of the compressor to maintain the produced water temperature at the setpoint value set via the controller
Domestic hot water production The unit activates in heating mode to maintain the temperature of a DHW boiler at the setpoint. A 3-way diverter valve (not supplied) and a temperature probe, supplied with the unit, are required to be inserted into a well in the DHW boiler.
Additional energy sources These sources can be activated to supplement or replace the heat pump during heating or DHW production and in case the heat pump is not working.
Cascade management of multiple units Possibility of managing up to 6 units in cascade even with different power ratings with a single controller connected to the Master. In the event of an anomaly in one "Slave", the others can operate normally.
Electric resistance for DHW boiler It is possible to manage an eventual integration and/or reserve electric resistance and for the anti-legionella function
Fast ACS Manually activated function that allows you to give priority to domestic hot water by bringing the ACS boiler to the set point in the shortest possible time
Anti-legionella function: Weekly anti-legionella cycles can be set. The heat pump must be integrated with an electric heating element for the DHW boiler or a boiler.
Silent mode There are 2 levels of silence which, if activated, according to a time schedule, lead to a reduction in the maximum frequency of the compressor and the fan speed to reduce the noise emitted, perhaps at night, and the power absorbed by the unit.
ON/OFF The unit can be activated and deactivated via an external contact. It can be managed from the controller's keyboard.
Hot/Cold The unit can be switched on and off in cold and hot mode via 2 external contacts
ECO Possibility to define time slots and related setpoints for ECO modes in hot and cold mode
Weekly programming Allows for different time programming for each day of the week, defining the working mode and setpoint for each band
Antifreeze protection Guaranteed up to an external air temperature of -20°C thanks to the heat pump itself operating in heating mode, the standard antifreeze electric resistance and the electric booster if installed.
Remote control of the unit via APP Available for iOS and Android
CONTINUE SHOPPING
!