SCHEDA TECNICA
The FALKO OC series is designed for:
Heat, cool and dehumidify environments.
Emit heat output with high efficiency at high as well as low flow temperatures (excellent for heat pump systems).
Compatible with both traditional boilers, as well as condensing boilers, solar systems and heat pumps.
To be positioned inside false ceilings.
Build simple ducted networks, also using the range of available accessories, for air distribution in all rooms.
The rear intake can be oriented downwards on site and channelled to a single room or drawn from a single grille underneath the unit.
Ideal Clima Falko OC Standard 510 TCM05A Ceiling Fan Coil Unit Control Excluded
Total cooling power 7°C (1) W 2'788
Sensible cooling capacity W 2'019
Water flow rate l/min 8
Pressure drop only Falko OC kPa 36
Pressure drop 2 and 3 way valves KVs=1.7 kPa 1.2
Heating power 45 °C (2) W 3'360
Water flow rate l/min 10
Falko OC pressure drop kPa 53
Pressure drop 3-way valve KVs=1.7 kPA2
Air flow rate max. speed at 30 Pa mmc/h 510
Max. speed sound pressure (*) dB (A) 42

FALKO OC 
Falko OC is the fan coil for installation in false ceilings.
Thanks to its height of just 24 cm and its high-efficiency exchange battery, it can be installed inside false ceilings in residential settings.
The rear air intake can be converted to bottom air intake on site. The condensate collection tray has a DN 20 outlet.
The motor has three in-phase inputs for speed selection. The frame is made of galvanized sheet metal. The air filter is removable, on the intake. The 3/4" F water connections on the left side are reversible on site.
The FALKO OC series is designed for:
- Heat, cool and dehumidify rooms.
- Emit thermal power with high efficiency at high as well as low flow temperatures (excellent for heat pump systems).
- Compatible with both traditional boilers, as well as condensing boilers, solar systems and heat pumps.
- To be positioned inside false ceilings.
- Build simple ducted networks, also using the range of available accessories, for air distribution in all rooms.
- The rear intake can be oriented downwards on site and channelled to a single room or extracted from a single grille underneath the unit.

Falko OC can be controlled, alternatively:
- From the built-in three-speed chronothermostat
- From a generic three-speed fan coil thermostat, capable of providing in-phase contacts

It can be converted on site, with a simple screwdriver, from the version with "rear" shooting to the version with "bottom" shooting.
In this way, channeling is extremely easy, thanks to the range of accessories available, which includes modular supply and return plenums with push-fit fittings.